SF6 gas leak rate : <1‰

Rated current : 630A

Lightning impulse withstand voltage : 85KV

Rated voltage : 12KV

Rated peak withstand current : 50KA

Secondary circuit power frequency withstand voltage : 2KV

Enclosure Protection Class : IP66

Rated short time withstand current : 20 KA/3s

Place of Origin : China

Rated current breaking times : 100Time

Power frequency withstand voltage / phase-phase / to ground / fracture : 42/48KV

Rated closed-loop breaking current : 630A

SF6 Gas Pressure (Relative & Absolute Pressure) : 40kPa

Rated cable breaking current : 10A

Applicable Cable Cross-section : ≤400mm²

Contact Now

Overview

The switching station is an important auxiliary power supply facility in medium-voltage power distribution networks, acting as the downstream hub of ring network power supply systems.

It undertakes voltage transformation, circuit distribution, fault isolation and flexible power supply switching. It can effectively optimize regional power grid topology, shorten power supply radius, and greatly improve power supply reliability and power quality. Widely applied in urban & rural power grids, industrial parks and residential communities, it is also known as an outdoor cable branch distribution station.

Application Areas

Reasonable power supply range division in distribution networks ensures stable and reliable power supply for ring network, branch and terminal loads. Its switching operations will not interfere with normal grid operation and user power consumption.

Meanwhile, it optimizes grid structure, narrows power failure fault scope, reduces line loss and grid operation load, and realizes flexible zoning coordination between power feeders and load sections.

Use Conditions
  1. Ambient temperature: -35℃ to +40℃
  2. Maximum installation altitude: ≤ 2000m above sea level
  3. Relative humidity: daily average ≤95%, monthly average ≤90%
  4. Seismic resistance grade: Grade 8
Technical Parameters
Standard Configuration & Features
  • Reserved load expansion interface
  • Integrated overload & earth fault protection
  • Load break switch operating mechanism: AC220V/110V
  • Rated voltage: 12kV
  • Power frequency withstand voltage: 42/85kV
  • Lightning impulse withstand voltage: 75/95kV
  • Rated current: 630A
  • Rated short-time withstand current: 20kA/3s
  • Rated peak withstand current: 50kA
  • Enclosure protection class: IP66
  • SF6 gas pressure: 40kPa
  • SF6 gas leakage rate: ≤0.1%
  • Applicable cable cross-section: ≤400mm²